Why Stairs & Railing Systems Do Not Require Special Inspections

Steel staircase

Does the International Building Code (IBC) require special inspections of welding on stairs and railing systems? You may be surprised to know that the answer to this important question is NO. Even if the welded stairs and railing systems are in a high-rise building and the stairs serve as the only exit (other than the elevator), the IBC still does not require special inspections. The building official, the structural engineer of record (SER), and the applicable statewide building code COULD require special inspections of the welding for the stairs and railing system, but this happens very rarely.

The IBC used to require these welding special inspections in Section 1704.3 (Chapter 17) from IBC 2000 through IBC 2009. However, when IBC 2012 was published, the steel portion of Chapter 17 reflected massive changes in steel special inspections. This included the deletion of Table 1704.3, which listed most code-required steel special inspections (at the time). The IBC 2012 edition also deleted pertinent verbiage from Section 1704.3 that clearly required special inspections of welded stairs and railing systems.

IBC 2012 shifted special inspection reliance to AISC 360, Chapter N, and deleted AWS D1.1 links. AISC 360 adopts AISC 303, “Code of Standard Practice for Steel Buildings and Bridges,” and AISC 303, Section 2.1, does not classify stairs and railing systems as structural steel. Instead, Section 2.2 lists stairs and railing systems as “other steel.” (See data footnote below.) Because AISC 360 adopts AISC 303, it also incorporates the definition of structural steel in Section 2.1 and designates steel stairs and railing systems as “other steel,” as AISC 303, Section 2.2, does. This is the root of the problem as to why special inspections are not required by code for welding on steel stairs and railing systems.

Most project steel specifications require special inspections of structural steel because the IBC requires them. However, because AISC 303 does not classify steel stairs and railing systems as structural steel but as “other” steel, it exempts the project stairs and railing systems from special inspections. To help ensure the project stairs are subject to special inspections, registered design professionals should require them in Sections 01400 and 05500 of the project specifications.


AISC 303 “Code of Standard Practice for Steel Buildings”

Section 2.1 Structural steel shall consist of the elements of the structural frame that are shown and sized in the structural design documents, essential to support the design loads.

Section 2.2 Structural steel shall not include other steel, iron or metal items that are not, generally, described in Section 2.1. (The Section 2.2 list includes stairs and handrails).


Written by: Alan S. Tuck | Published by: Froehling & Robertson, Inc. | If you have any questions, please contact us at speakingincode@fandr.com

Disclaimer: The information contained in this publication is provided for general informational and educational purposes only. While reasonable efforts are made to ensure its accuracy, Froehling & Robertson, Inc. (F&R) makes no representations or warranties regarding the accuracy, completeness, or applicability of the information presented. F&R disclaims responsibility and liability for any errors, omissions, or the interpretation, use, or application of this information. Readers are encouraged to independently verify applicable codes, standards, and requirements before relying upon the information provided.